Medentra Dental - Explore a comprehensive selection of premium dental instruments designed for precision and reliability. Our dental tools are crafted to meet the highest industry standards, ensuring optimal performance for dental professionals. - Shop Top Quality Surgical, Beauty and Dental Instruments


+44 (0) 845 548 9850 | sales@medentra-dental.com
     

Shopping Cart

You have no items in your shopping cart.



Dental Dentist Amalgam Carrier Amalgam Gun Double End Restorative Dentistry Lab

Be the first to review this product

Availability: In stock

Regular Price: £15.00

Special Price: £7.49

OR

Quick Overview

A Dental Amalgam Carrier, commonly known as an Amalgam Gun or Amalgam Carrier Gun, is a versatile tool in dentistry primarily used for placing and condensing dental amalgam during restorative procedures. The term "double" might refer to a double-ended amalgam carrier, which has different tip sizes on each end for added flexibility. Here are the primary uses of a Dental Amalgam Carrier Gun:

Amalgam Placement:

The primary function of the amalgam carrier is to load, carry, and dispense dental amalgam into the prepared tooth cavity. Dental amalgam is a mixture of metals, including mercury, silver, tin, and copper, used for filling cavities caused by tooth decay.
Condensation of Amalgam:

After dispensing the amalgam into the tooth cavity, the dentist uses the amalgam carrier to compact or condense the amalgam material. This ensures that the filling is densely packed and forms a solid restoration within the tooth.
Two-Ended Design (Double):

The "double" aspect might refer to a double-ended amalgam carrier, which typically has different-sized tips on each end. This allows the dentist to choose the appropriate tip for the size of the cavity being filled, adding flexibility and precision to the restoration process.
Versatility in Tooth Restorations:

The amalgam carrier is a versatile tool used in various tooth restorations, including dental fillings for caries (cavities), core build-ups, and other restorative procedures.
Single-Handed Operation:

Amalgam carriers are designed for single-handed operation, allowing dentists to have better control and maneuverability during the placement and condensation of dental amalgam.
Minimizing Mercury Exposure:

Dental professionals take precautions to minimize mercury exposure during the use of amalgam carriers. Proper handling techniques and infection control protocols are followed to ensure the safety of both the patient and the dental team.
The amalgam carrier plays a crucial role in traditional restorative dentistry, although the use of dental amalgam has declined in recent years due to concerns about mercury content and the increasing popularity of alternative restorative materials. Dental professionals may choose alternative materials based on patient preferences, aesthetics, and advancements in dental technology.

Dental Dentist Amalgam Carrier Amalgam Gun Double End Restorative Dentistry Lab

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

 

1. German austenitic standard stainless steel.
2. Highly polished & aesthetic finish.
3. 3 year product guarantee.
4. Top quality, competitive price.
5. Highly resistant to corrosion and rust.
6. Fully autoclavable / reusable.
7. Precisely crafted for exact use.
8. Fully compliant with ISO, FDA and CE standards.
9. 30 Days money back guarantee.
10. 100% satisfaction guaranteed

 

PRODUCT GUARANTEE 


  • 100% satisfaction guaranteed.
  • If for any reason you are not satisfied, please don`t leave negative feedback. Contact us and we will try our best to satisfy you and receive your positive feedback.
  • 30-day money-back guarantee if not satisfied.
  • 3-year comprehensive product guarantee from the date of delivery. If for any reason the instrument breaks down within 3 years of purchase, simply send us the item and proof of purchase. We will then send you a brand new replacement. No questions asked.
  • All instruments are packaged in Medentra branded packaging with a 3-year guarantee card.

 

MEDENTRA (MANUFACTURER) RECOMMENDED INSTRUCTIONS FOR CARE AND HANDLING.


RINSE AND CLEAN

EN: Inspect, clean and sterilize before each use. Be sure of cleaning all residual cleaning compounds, as they can cause stains.
ES: Inspeccione, limpie y esterilice antes de cada uso. Asegurese de limpiar todos los restosorganicos antes de la esterilizacion, ya que pueden causar manchas.
DE: Vor gedem Gabrauch uberprufen, reinigen und sterilisieren. Reinigen Sie vor der Sterilization alle organischen Ruckstande, da diese Flecken verursachen konnen.

 

ULTRASONIC CLEANER

EN: Use only recommended chemicals, do not disinfect with phenols. Rinse with running water.
ES: Utilice unicamente los productos quimicos recomendados, no disinfecte con Fenols. Enjuague con agua corriente.
DE: Verwenden Sie nur die empfohlenen Chemikalian, desinfizieren Sie nicht mit Phenolen. Mit flieBendem Wasser abspulen.

 

SHARPEN AND LUBRICATE


EN: Dry the instruments completely after rinsing and before sterilization. Use Arkansan/Indian sharpening stones with lubricant and specific sharpening oils. Lubricate the moving parts with antioxidant dental high density lubricants.
ES: Secar totalmente los instrumentos despues del enjuague y antes cada esterlizacion. Use Piedras de afilado Arkansas/India con Lubricantes y Aceites de afilados especificos. Lubique las Partes moviles con lubricantes de alta densidad dentales antioxidantes.
DE: Vor jeder Sterilisation trocknen. Verwenden Sie Arkansan/Indische Schleifsteine mit Gleitmittel und speziellen Schleifölen. Mit hochdichten Zahnatioxidantien schmieren.

 

PACKING AND STERILIZATION

 

EN: Sterilize for at least 5 minute at 273° F / 134° C or 20 minute at 250° F / 121° C. Do not heat above 350° F / 177° C.
ES: Esterilizar durante al menbon 5 min a 273° F / 134° C o 20 min a 250° F / 121° C. No caliente por encima 350° F / 177° C.
DE: Mindestens 5 Min bei 134° C oder 20 Min bei 121° C sterilisieren. Nicht uber 177° C erhitzen.

 

STORAGE AND USE

 

EN: Store in a place without humidity and without extreme temperatures. Store in rolls/bags for sterilization.Intended use only by Dental Professionals. Brand new instrument should be cleaned prior to the first sterilization.
ES: Almacenar en lugar sin humedades y sin temperaturas extremas. Almacenar en Rollos/Bolsas para esterilizacion.Para uso unicamente por Profesionales Dentales. Los instrumentos nuevos deben limpiarse antes de la primera esterilizacion.
DE: An einem Ort ohne Feuchtigkeit und ohne extreme Temperaturen lagern. Zur Sterilisation in Rollen / Beuteln aufbewahren.Nur zur Verwendung durch Zahnarzte. Neue Instrumente Mussen vor der ersten Sterilisation gereinigt warden.

 

FEEDBACK 

 

Our only priority is customer satisfaction in all respects, including quality and service. If for any reason you are not satisfied with our product, please send us a message. We will process this within 24 hours in order to keep you satisfied by providing you with our dedicated service at all levels.

 

OTHER GREAT VALUE SERVICES FOR DENTAL SURGERY, INSTITUTIONS AND COMPANIES

 

We can individualize the products you have ordered with your brand name / name of the dental clinic / name of the institution etc. This service is absolutely free and at no additional cost. (MOQ applies). For wholesale business inquiries, please send us a message and we will get back to you within 24 hours.

 

Manufacturer Medentra®

Use spaces to separate tags. Use single quotes (') for phrases.


Write Your Own Review

You're reviewing: Dental Dentist Amalgam Carrier Amalgam Gun Double End Restorative Dentistry Lab

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality