Medentra Dental - Explore a comprehensive selection of premium dental instruments designed for precision and reliability. Our dental tools are crafted to meet the highest industry standards, ensuring optimal performance for dental professionals. - Shop Top Quality Surgical, Beauty and Dental Instruments


+44 (0) 845 548 9850 | sales@medentra-dental.com
     

Shopping Cart

You have no items in your shopping cart.



Dental Syringe Aspirating Anesthetics 1.8ml Gold Coated Barrel AMR+EUR Thread CE

Be the first to review this product

Availability: In stock

Regular Price: £20.00

Special Price: £9.99

OR

Quick Overview

A dental syringe used for aspirating anesthetics, typically with a volume of 1.8ml, serves specific purposes in dentistry. Here are some of its primary uses:

Aspiration of Anesthetic Solution:

The primary function of a dental syringe for aspirating anesthetics is to allow the dentist to aspirate or withdraw a small amount of the injected anesthetic solution before fully administering it. This helps ensure that the needle is not within a blood vessel, preventing intravascular injection.
Safety and Accuracy:

Aspiration is a safety measure to avoid unintended injection of the anesthetic into blood vessels. This is crucial for preventing complications associated with intravascular injection, such as systemic toxicity.
Avoiding Complications:

By aspirating before injecting the full dose, the dentist can detect the presence of blood in the aspirated solution. If blood is present, it may indicate that the needle is in a blood vessel, and the injection should be halted to avoid complications.
Intraligamentary Injections:

Aspirating syringes are often used in certain injection techniques, such as intraligamentary injections, where precise placement of the anesthetic solution is crucial.
Preventing Systemic Toxicity:

Aspiration helps prevent systemic toxicity by ensuring that the anesthetic is not inadvertently injected into the bloodstream. Systemic toxicity can have serious consequences, and aspirating syringes are a safety measure to mitigate this risk.
Maxillofacial Surgery:

In more complex dental procedures, especially those involving maxillofacial surgery, aspirating syringes may be used to enhance precision in delivering local anesthesia.
Periodontal Procedures:

For periodontal procedures where precision is essential, aspirating syringes can be beneficial to ensure that the anesthetic is delivered to the target area without complications.
Pediatric Dentistry:

Aspirating syringes are employed in pediatric dentistry to enhance safety during local anesthesia administration. The smaller volume (1.8ml) makes it suitable for use in children.
In summary, a dental syringe for aspirating anesthetics, with a volume of 1.8ml, is a specialized tool designed to enhance safety and accuracy during local anesthesia administration. It plays a crucial role in preventing complications associated with inadvertent intravascular injection and systemic toxicity, particularly in situations where precise injection placement is essential.

Dental Syringe Aspirating Anesthetics 1.8ml Gold Coated Barrel AMR+EUR Thread CE

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

x1 Set of 3 Pvs,  Amalgam Carrier Gun Set of 3 Restorative Instruments Dental Tools Amalgam Carrier Amalgam Gun 30°, 45°, 90° 

 

1. German austenitic standard stainless steel.
2. Highly polished & aesthetic finish.
3. 3 year product guarantee.
4. Top quality, competitive price.
5. Highly resistant to corrosion and rust.
6. Fully autoclavable / reusable.
7. Precisely crafted for exact use.
8. Fully compliant with ISO, FDA and CE standards.
9. 30 Days money back guarantee.
10. 100% satisfaction guaranteed

 

PRODUCT GUARANTEE 


  • 100% satisfaction guaranteed.
  • If for any reason you are not satisfied, please don`t leave negative feedback. Contact us and we will try our best to satisfy you and receive your positive feedback.
  • 30-day money-back guarantee if not satisfied.
  • 3-year comprehensive product guarantee from the date of delivery. If for any reason the instrument breaks down within 3 years of purchase, simply send us the item and proof of purchase. We will then send you a brand new replacement. No questions asked.
  • All instruments are packaged in Medentra branded packaging with a 3-year guarantee card.

 

MEDENTRA (MANUFACTURER) RECOMMENDED INSTRUCTIONS FOR CARE AND HANDLING.


RINSE AND CLEAN

EN: Inspect, clean and sterilize before each use. Be sure of cleaning all residual cleaning compounds, as they can cause stains.
ES: Inspeccione, limpie y esterilice antes de cada uso. Asegurese de limpiar todos los restosorganicos antes de la esterilizacion, ya que pueden causar manchas.
DE: Vor gedem Gabrauch uberprufen, reinigen und sterilisieren. Reinigen Sie vor der Sterilization alle organischen Ruckstande, da diese Flecken verursachen konnen.

 

ULTRASONIC CLEANER

EN: Use only recommended chemicals, do not disinfect with phenols. Rinse with running water.
ES: Utilice unicamente los productos quimicos recomendados, no disinfecte con Fenols. Enjuague con agua corriente.
DE: Verwenden Sie nur die empfohlenen Chemikalian, desinfizieren Sie nicht mit Phenolen. Mit flieBendem Wasser abspulen.

 

SHARPEN AND LUBRICATE


EN: Dry the instruments completely after rinsing and before sterilization. Use Arkansan/Indian sharpening stones with lubricant and specific sharpening oils. Lubricate the moving parts with antioxidant dental high density lubricants.
ES: Secar totalmente los instrumentos despues del enjuague y antes cada esterlizacion. Use Piedras de afilado Arkansas/India con Lubricantes y Aceites de afilados especificos. Lubique las Partes moviles con lubricantes de alta densidad dentales antioxidantes.
DE: Vor jeder Sterilisation trocknen. Verwenden Sie Arkansan/Indische Schleifsteine mit Gleitmittel und speziellen Schleifölen. Mit hochdichten Zahnatioxidantien schmieren.

 

PACKING AND STERILIZATION

 

EN: Sterilize for at least 5 minute at 273° F / 134° C or 20 minute at 250° F / 121° C. Do not heat above 350° F / 177° C.
ES: Esterilizar durante al menbon 5 min a 273° F / 134° C o 20 min a 250° F / 121° C. No caliente por encima 350° F / 177° C.
DE: Mindestens 5 Min bei 134° C oder 20 Min bei 121° C sterilisieren. Nicht uber 177° C erhitzen.

 

STORAGE AND USE

 

EN: Store in a place without humidity and without extreme temperatures. Store in rolls/bags for sterilization.Intended use only by Dental Professionals. Brand new instrument should be cleaned prior to the first sterilization.
ES: Almacenar en lugar sin humedades y sin temperaturas extremas. Almacenar en Rollos/Bolsas para esterilizacion.Para uso unicamente por Profesionales Dentales. Los instrumentos nuevos deben limpiarse antes de la primera esterilizacion.
DE: An einem Ort ohne Feuchtigkeit und ohne extreme Temperaturen lagern. Zur Sterilisation in Rollen / Beuteln aufbewahren.Nur zur Verwendung durch Zahnarzte. Neue Instrumente Mussen vor der ersten Sterilisation gereinigt warden.

 

FEEDBACK 

 

Our only priority is customer satisfaction in all respects, including quality and service. If for any reason you are not satisfied with our product, please send us a message. We will process this within 24 hours in order to keep you satisfied by providing you with our dedicated service at all levels.

 

OTHER GREAT VALUE SERVICES FOR DENTAL SURGERY, INSTITUTIONS AND COMPANIES

 

We can individualize the products you have ordered with your brand name / name of the dental clinic / name of the institution etc. This service is absolutely free and at no additional cost. (MOQ applies). For wholesale business inquiries, please send us a message and we will get back to you within 24 hours.

 

Manufacturer Medentra®

Use spaces to separate tags. Use single quotes (') for phrases.


Write Your Own Review

You're reviewing: Dental Syringe Aspirating Anesthetics 1.8ml Gold Coated Barrel AMR+EUR Thread CE

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality